header valves
Valves & Actuation

Series 19 Modulating Failsafe Ball Valves

series-19-on-type-21-ball-valve

Series 19 Smart SAV Modulating Failsafe Electric Actuator - Ball Valve Packages

The Series 19 modulating failsafe combines the features of a modulating unit with the reliability of a failsafe unit. With all of the same features of the modulating unit, the modulating failsafe employs a capacitor discharge design for the failsafe ability. When the power supply is lost, the failsafe system will cycle the valve to a predetermined position (open, closed, or as is). Series 19 SAV Smart Pack® electric actuators can be factory-mounted on Type-21/21a and Type-21a SST ball valves and Type-23 Multiport ball valves. Choose from PVC, CPVC, PP, and PVDF valve bodies, and socket or threaded end connectors (ball valves). One part number for valve and actuator packages makes ordering easy. All actuated Smart Packs® are available in the four different models: on/off, modulating, failsafe, and modulating failsafe.

AIA FindUsIn MasterSpec Deltek Specpoint 2c full CMYK 01

Button CAV On Off

Button CAV Fail Safe

Button Smart On Off

Button Failsafe

Button Modulating

Button Mod Failsafe

Multiturn On Off 01

Multiturn Modulating 01

 

 

 

 

New Modulating Fail Safe

Series 19 Valve/Actuator Packages

Ball Valves

Series 19 on Type 21 Series 19 on Type 23
Button Type 21 Button Type 23
Ideal Applications Include:

Water treatment, water features, fountains, aquariums, landfills, swimming pools, power plants, mining, transportation, chemical processing

Sizes:

S20, S50, S110

Amp Draw:

0.18 Amp for S20, 0.24 Amp for S50, 0.84 for S110                

Cycle Time:

Per 90 degrees: 10 seconds

Torque:

177 in-lbs to 973 in-lbs

Electrical Connection:

NEMA 4X cable gland with two-meter color-coded cable

Enclosure:

NEMA 4X

Voltage:

95 VAC to 265 VAC 1Ph 50/60 Hz

24 AC/DC

Max Temp:

150° F

Features/Benefits

  • Compact: Perfect for OEM and skid manufacturers
  • OLED Screen: Displays input command, position status, alert conditions
  • Push Buttons: Used to calibrate/adjust end positions and operate local controls
  • Multi-voltage: 95 VAC to 265 VAC or 24 VAC/VDC
  • Motor: Reversing, brushless DC motor
  • Gear Train: Permanently lubricated steel gears
  • Corrosion Resistant Enclosure: NEMA 4X enclosure with stainless steel trim
  • ISO mounting configuration
  • Electrical Connection: NEMA 4X cable gland with two-meter cable length
  • Position Indication: Highly visible beacon position indicator
  • LED Position Indication: RED closed, GREEN open, BLUE fault
  • Manual Override: Manually cycle valve via electroless nickel-plated hex key
  • Selectable Control Signal: User can select 4-20 mA, 0-20 mA, 0-10 VDC,2-10 VDC, or 1-5 VDC (size 20 is specifically a current control signal or a voltage control signal)
  • Reverse Acting: User can select standard operation or reverse acting
  • Selectable Fail Position: If control signal is lost, the unit can be calibrated to fail as is, fail open, or fail close
  • Transmitter: Current or voltage transmitter (matching the control signal) is standard equipment
  • Capacitor Discharge System: A capacitor is used in place of batteries for failsafe mode
  • QR Code: Links to user manual; includes wiring schematic
  • RoHS Compliant

Resources

Data Sheets and Catalogs
Technical Resources
Training & Videos