Ideal Applications Include:

Maintenance, manual control, protection against computer signal loss

  • For use with Series 19 Electric Actuators
  • NEMA Type 4X enclosure constructed of fiberglass polyester
  • Stainless steel trim
  • For use with with Series 19 Electric Actuators
  • NEMA Type 4X enclosure constructed of fiberglass polyester
  • Stainless steel trim
  • Captive cover gasket
  • Captive cover screws
  • Two position selector switch (open/close)
  • Three position selector switch (hand/off/auto)
  • Terminal block for the landing of the Series 19 electric actuator flying leads
  • Three indication lights (green – open; red – closed; blue – alarm)
  • Three dry relays – SPDT, 10A (open confirmation [CR1], closed confirmation [CR2], alarm [CR3])
  • Series 19 CAV
  • Series 19 SAV
  • Series 19 MAV
  • Contact factory for specific applications

Specifications:

Sizes:

S20, S50, S110, S400

Amp Draw:

0.34 Amp for S20, 0.39 Amp for S50,

1.24 Amp for S110, 1.83 Amp for S400

Cycle Time:

Per 90 degrees: 10 seconds

Torque:

177 in-lbs to 3540 in-lbs

Electrical Connection:

NEMA 4X cable gland with two-meter color-coded cable

Enclosure:

NEMA 4X

Voltage:

95 VAC to 265 VAC 1Ph 50/60 Hz

24 AC/DC

Max Temp:

150° F

  • Compact: Perfect for OEM and skid manufacturers
  • OLED Screen: Displays input command, position status, alert conditions
  • Push Buttons: Used to calibrate/adjust end positions and operate local controls
  • Multi-voltage: 95 VAC to 265 VAC or 24 VAC/VDC
  • Motor: Reversing, brushless DC motor
  • Gear Train: Permanently lubricated steel gears
  • Corrosion Resistant Enclosure: NEMA 4X enclosure with stainless steel trim
  • ISO mounting configuration
  • Electrical Connection: NEMA 4X cable gland with two-meter cable length
  • Position Indication: Highly visible beacon position indicator
  • LED Position Indication: RED closed, GREEN open, BLUE fault
  • Manual Override: Manually cycle valve via electroless nickel-plated hex key
  • Selectable Control Signal: User can select 4-20 mA, 0-20 mA, 0-10 VDC, 2-10 VDC, or 1-5 VDC (size 20 is specifically a current control signal or a voltage control signal)
  • Reverse Acting: User can select standard operation or reverse acting
  • Selectable Fail Position: If control signal is lost, the unit can be calibrated to fail as is, fail open, or fail close
  • Transmitter: Current or voltage transmitter (matching the control signal) is standard equipment
  • Capacitor Discharge System: A capacitor is used in place of batteries for failsafe mode
  • QR Code: Links to user manual; includes wiring schematic
  • RoHS Compliant

Specifications:

Sizes:

S20, S50

Amp Draw:

0.96 Amp for S20, 1.2 Amp for S50 (24 VAC/VDC)

0.24 Amp for S50 (95 VAC to 265 VAC)

Cycle Time:

Per cycle: 13 to 100 seconds

Torque:

177 in-lbs to 442 in-lbs

Electrical Connection:

NEMA 4X cable gland with two-meter cable

Enclosure:

NEMA 4X PC/PET enclosure with stainless steel trim

Type-14 Diaphragm Valve:

  • Compact: Perfect for OEM and skid manufacturers
  • OLED Screen: Displays input command, position status, alert conditions
  • Push Buttons: Used to calibrate, local controls
  • Multi-voltage: 24 VAC/VDC
  • Motor: Reversing, brushless DC motor
  • Gear Train: Permanently lubricated steel gears
  • Corrosion Resistant Enclosure: NEMA 4X PC/PET enclosure with stainless steel trim
  • Electrical Connection: NEMA 4X cable gland with two-meter cable
  • Visual Position Indication: Flat disc position indicator
  • LED Position Indication: RED closed, GREEN open, BLUE fault
  • Manual Override: Manually cycle valve via electroless nickel-plated hex key
  • Selectable Control Signal: User can select 4-20 mA, 0-20 mA, 0-10 VDC, 2-10 VDC, or 1-5 VDC (size 20 is specifically a current control signal or a voltage control signal)
  • Reverse Acting: User can select standard operation or reverse acting
  • Selectable Fail Position: If control signal is lost, the unit can be calibrated to fail as is, fail open, or fail close
  • Transmitter: Current or voltage transmitter (matching the control signal) is standard equipment
  • Alarm Contacts: Dry contacts rated 0.1 Amp @ 250 VAC, 0.5 Amp @ 30 VDC for alarm status (over torque, as an example)
  • QR Code: Links to user manual; includes wiring schematic
  • Space Heater: Internally wired to limit condensation
  • CE Compliant: All actuators are CE labeled and compliant
  • 70% Duty Cycle: Extended duty cycle is ideal for high cycling applications
  • Simple Wiring: Wiring technique is the same for all voltage units
  • Local Controls: Used with OLED and push buttons, a user can locally open or close units via password

Type-C Gate Valve:

  • Compact: Perfect for OEM and skid manufacturers
  • OLED Screen: Displays valve position, alarms (such as an over torque condition)
  • Push Buttons: Used to calibrate/adjust end positions, local controls
  • Multi-voltage: 95 VAC to 265 VAC, 24VAC/VDC
  • Motor: Reversing, brushless DC motor
  • Gear Train: Permanently lubricated steel gears
  • Corrosion Resistant Enclosure: NEMA 4X PC/PET enclosure with stainless steel trim
  • ISO mounting configuration
  • Electrical Connection: NEMA 4X cable gland with two-meter cable
  • Visual Position Indication: Flat disc position indicator
  • LED Position Indication: RED closed, GREEN open, BLUE fault
  • Manual Override: Manually cycle valve via electroless nickel-plated hex key
  • Auxiliary Contacts: Open and closed dry contacts rated 0.1 Amp @ 250 VAC, 0.5 Amp @ 30 VDC
  • Alarm Contacts: Dry contacts rated 0.1 Amp @ 250 VAC, 0.5 Amp @ 30 VDC for alarm status (over torque, as an example)
  • QR Code: Links to user manual; includes wiring schematic
  • Space Heater: Internally wired to limit condensation
  • CE Compliant: All actuators are CE labeled and compliant
  • 70% Duty Cycle: Extended duty cycle is ideal for high cycling applications
  • Simple Wiring: Wiring technique is the same for all voltage units
  • Local Controls: Used with OLED and push buttons, a user can locally open or close units via password

Specifications:

Sizes:

S20, S50, S110, S400

Amp Draw:

0.34 Amp for S20, 0.39 Amp for S50, 1.24 Amp for S110, 1.83 Amp for S400

Cycle Time:

Per 90 degrees: 10 seconds

Torque:

177 in-lbs to 3540 in-lbs

Electrical Connection:

NEMA 4X cable gland with two-meter color-coded cable

Enclosure:

NEMA 4X

Voltage:

95 VAC to 265 VAC 1Ph 50/60 Hz
24 AC/DC

Max Temp:

150° F

  • Compact: Perfect for OEM and skid manufacturers
  • OLED Screen: Displays input command, position status, alert conditions
  • Push Buttons: Used to calibrate/adjust end positions and operate local controls
  • Multi-voltage: 95 VAC to 265 VAC or 24 VAC/VDC
  • Motor: Reversing, brushless DC motor
  • Gear Train: Permanently lubricated steel gears
  • Corrosion Resistant Enclosure: NEMA 4X enclosure with stainless steel trim
  • ISO mounting configuration
  • Electrical Connection: NEMA 4X cable gland with two-meter cable length
  • Position Indication: Highly visible beacon position indicator
  • LED Position Indication: RED closed, GREEN open, BLUE fault
  • Manual Override: Manually cycle valve via electroless nickel-plated hex key
  • Selectable Control Signal: User can select 4-20 mA, 0-20 mA, 0-10 VDC, 2- 10 VDC, or 1-5 VDC (size 20 is specifically a current control signal or a voltage control signal)
  • Reverse Acting: User can select standard operation or reverse acting
  • Selectable Fail Position: If control signal is lost, the unit can be calibrated to fail as is, fail open, or fail close
  • Transmitter: Current or voltage transmitter (matching the control signal) is standard equipment
  • Alarm Contacts: Dry contacts rates 0.1 Amp @ 250 VAC, 0.5 Amp @ 30 VDC for alarm status (over torque, as an example)
  • Space Heater: Internally wired to limit condensation
  • QR Code: Links to user manual; includes wiring schematic
  • RoHS Compliant

Specifications:

Size:

C20 for 3/8″ – 2″ Omni® Type-27 Ball Valves

Amp Draw:

0.18 Amp

Cycle Time:

Per 90 degrees: 10 seconds

Torque:

177 in-lbs

Electrical Connection:

NEMA 4X cable gland with two-meter color coded cable

Enclosure:

NEMA 4X

Voltage:

95 VAC to 265 VAC 1Ph 50/60 Hz

24 AC/DC

Max Temp:

150° F

  • Compact: Perfect for OEM and skid manufacturers with a footprint of 2.75” x 4” up to a 2” ball valve
  • Multi-voltage: 95 VAC to 265 VAC or 24 VAC/VDC
  • Motor: Reversing, brushless DC motor
  • Capacitor Discharge System: A capacitor is used in place of batteries for failsafe mode
  • Fail Position: Fail close is standard; fail as is, or fail open are options
  • Gear Train: Permanently lubricated steel gears
  • Corrosion Resistant Enclosure: NEMA 4X enclosure with stainless steel trim
  • ISO mounting configuration
  • Electrical Connection: NEMA 4X cable gland with two-meter cable
  • Position Indication: Highly visible beacon position indicator
  • LED Position Indication: RED closed, GREEN open
  • Manual Override: Manually cycle valve via electroless nickel-plated hex key
  • Auxiliary Contacts: Open and closed dry contacts rated 0.1 Amp @ 250 VAC, 0.5 Amp @ 30 VDC
  • Space Heater: Internally wired to limit condensation
  • CE Compliant: All actuators are CE labeled and compliant
  • 75% Duty Cycle: Extended duty cycle is ideal for high cycling applications
  • QR Code: Links to user manual; includes wiring schematic
  • Simple Wiring: Wiring technique is the same for all voltage units
  • RoHS Compliant

Specifications:

Sizes:

S20FS, S50FS, S110FS, S400FS

Amp Draw:

0.34 Amp for S20, 0.39 Amp for S50, 1.24 Amp for S110, 1.83 Amp for S400

Cycle Time:

Per 90 degrees: 10 seconds

Torque:

177 in-lbs to 3540 in-lbs

Electrical Connection:

NEMA 4X cable gland with two-meter color-coded cable

Enclosure:

NEMA 4X

Voltage:

95 VAC to 265 VAC 1Ph 50/60 Hz
24 AC/DC

Max Temp:

150° F

  • Compact: Perfect for OEM and skid manufacturers
  • OLED Screen: Displays valve position and alarms
  • Push Buttons: Used to calibrate/adjust end positions and operate local controls
  • Multi-voltage: 95 VAC to 265 VAC or 24 VAC/VDC
  • Motor: Reversing, brushless DC motor
  • Capacitor Discharge System: A capacitor is used in place of batteries for failsafe mode
  • Selectable Fail Position: Fail close is standard; fail as is, or fail open are options
  • Corrosion Resistant Enclosure: NEMA 4X enclosure with stainless steel trim
  • Electrical Connection: NEMA 4X cable gland with two-meter cable length
  • LED Position Indication: RED closed, GREEN open, BLUE fault
  • Manual Override: Manually cycle valve via electroless nickel-plated hex key
  • Auxiliary Contacts: Open and close dry contacts rated 0.1 Amp @ 250 VAC, 0.5 Amp @ 30 VDC
  • Alarm Contacts: Dry contacts rated 0.1 Amp @ 250 VAC, 0.5 Amp @ 30 VDC for alarm status (over torque, as an example)
  • Space Heater: Internally wired to limit condensation
  • CE Compliant: All actuators are CE labeled and compliant
  • 75% Duty Cycle: Ideal for high cycling applications
  • Output Torque: Series 19 electric actuators have an output torque range from 177 in-lbs to 3540 in-lbs
  • Simple Wiring: Wiring technique is the same for all voltage units
  • Local Controls: Used with OLED and push buttons, a user can locally open or close units via password
  • QR Code: Links to user manual; includes wiring schematic
  • RoHS Compliant

Specifications:

Sizes:

S20, S50

Amp Draw:

0.96 Amp for S20, 1.2 Amp for S50 (24 VAC/VDC)

0.24 Amp for S50 (95 VAC to 265 VAC)

Cycle Time:

Per cycle: 13 to 100 seconds

Torque:

177 in-lbs to 442 in-lbs

Electrical Connection:

NEMA 4X cable gland with two-meter cable

Enclosure:

NEMA 4X PC/PET enclosure with stainless steel trim

Voltage:

95 VAC to 265 VAC

24 VAC/VDC

Max Temp:

150° F

  • Compact: Perfect for OEM and skid manufacturers
  • OLED Screen: Displays valve position, alarms (such as an over torque condition)
  • Push Buttons: Used to calibrate/adjust end positions, local controls
  • Multi-voltage: 95 VAC to 265 VAC or 24 VAC/VDC
  • Motor: Reversing, brushless DC motor
  • Gear Train: Permanently lubricated steel gears
  • Corrosion Resistant Enclosure: NEMA 4X PC/PET enclosure with stainless steel trim
  • ISO mounting configuration
  • Electrical Connection: NEMA 4X cable gland with two-meter cable
  • Visual Position Indication: Flat disc position indicator
  • LED Position Indication: RED closed, GREEN open, BLUE fault
  • Manual Override: Manually cycle valve via electroless nickel-plated hex key
  • Auxiliary Contacts: Open and closed dry contacts rated 0.1 Amp @ 250 VAC, 0.5 Amp @ 30 VDC
  • Alarm Contacts: Dry contacts rated 0.1 Amp @ 250 VAC, 0.5 Amp @ 30 VDC for alarm status (over torque, as an example)
  • QR Code: Links to user manual; includes wiring schematic
  • Space Heater: Internally wired to limit condensation
  • CE Compliant: All actuators are CE labeled and compliant
  • 70% Duty Cycle: Extended duty cycle is ideal for high cycling applications
  • Simple Wiring: Wiring technique is the same for all voltage units
  • Local Controls: Used with OLED and push buttons, a user can locally open or close units via password

Resources:

Data Sheets

Ideal Applications Include:

Remote locations, locations with no air supply, colder temperatures, smaller valves, low cost applications

Specifications:

Sizes:

C20 for 3/8″ – 2″ Omni® Type-27 ball valves

C20 for 1/2″ – 2″ Type-21 ball valves and Type-23 Multiport™ ball valves

Amp Draw:

0.18 Amp

Cycle Time:

Per 90 degrees: 10 seconds

Torque:

177 in-lbs

Electrical Connection:

NEMA 4X cable gland with two-meter color-coded cable

Enclosure:

NEMA 4X

Voltage:

95 VAC to 265 VAC 1Ph 50/60 Hz

24 AC/DC

Max Temp:

150° F

  • Compact: Compact and lightweight actuated valve package that is ideal for OEMs
  • Motor: Reversing, brushless DC motor
  • Multi-voltage: 95 VAC to 265 VAC or 24 VAC/VDC
  • Gear Train: Permanently lubricated solid gears
  • Corrosion Resistant Enclosure: NEMA 4X enclosure with stainless steel trim
  • Position Indication: Highly visible dome position indicator
  • LED Position Indication: RED closed, GREEN open
  • Manual Override: Manually cycle valve via electroless nickel-plated hex key
  • Auxiliary Contacts: Open and closed dry contacts rated 0.1 Amp @ 250 VAC, 0.5 Amp @ 30 VDC
  • Space Heater: A two-watt heater is internally wired to limit condensation
  • QR Code: Links to user manual; includes wiring schematic
  • RoHS Compliant

Specifications:

Sizes:

S20, S50, S110, S400

Amp Draw:

0.34 Amp for S20, 0.39 Amp for S50, 1.24 Amp for S110, 1.83 Amp for S400

Cycle Time:

Per 90 degrees: 10 seconds

Torque:

177 in-lbs to 3540 in-lbs

Electrical Connection:

NEMA 4X cable gland with two-meter color-coded cable

Enclosure:

NEMA 4X

Voltage:

95 VAC to 265 VAC 1Ph 50/60 Hz
24 AC/DC

Max Temp:

150° F

  • Compact: Perfect for OEM and skid manufacturers
  • OLED Screen: Displays valve position, alarms (such as an over torque condition)
  • Push Buttons: Used to calibrate/adjust end positions and operate local controls
  • Multi-voltage: 95 VAC to 265 VAC or 24 VAC/VDC
  • Position Indication: Highly visible beacon position indicator
  • LED Position Indication: RED closed, GREEN open, BLUE fault
  • Manual Override: Manually cycle valve via electroless nickle-plated hex key
  • Auxiliary contacts: Open and closed dry contacts rated 0.1 Amp @ 250 VAC, 0.5 Amp @ 30 VDC
  • Space Heater: Internally wired to limit condensation
  • QR Code: Links to user manual; includes wiring schematic
  • RoHS Compliant
Asahi/America - Your Experts in Plastics logo
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.