The flow through a globe valve follows a course that changes direction nearly 90º twice. But, because the seating of a globe valve is parallel to the line of flow of the liquid, the valve can be used to throttle the flow to any required degree or to give positive shut-offs. The economy and dependability of the Asahi/America globe valve make it desirable for many applications where this pressure drop is not critical. These valves are designed for manual operation only. |
Precise flow control Solid thermoplastic valve body provides excellent corrosion resistance PTFE bellows stem seal eliminates old style packing glands and minimizes maintenance Positive bubble-tight shut-off Plug and seat can be changed to accommodate a variety of valve coefficients (Cv) Plug (trim) can be characterized (linear or equal percentage) per requirements (see below) No metal to media contact Extremely corrosion resistant actuator constructed of glass-filled polyester (PEG) with stainless stell trim Maximum required air pressure is 90 psi 3-15 psi direct acting for sizes up to 1"
|
Sizes:1/2" - 4" Materials: PVC, PP, PVDF and PTFE Model: Flanged (ANSI) Stem Seal: PTFE Bellows Valve Seal: FKM,, EPDM and PTFE encapsulated FKM Flow Characteristics: Linear or equal percentage Rangeability: 1: 50 for 1/2" - 3"; 1: 30 for 4"
| |
|
3-15 psi pneumatic positioner 4-20mA electro-pneumatic positioner 4-20mA output transmitter Extra (auxiliary) limit switches
|
|
Chemical Processing Water & Wastewater Landfills Irrigation Food Processing Mining
|